R-401A PT Chart

R-401A saturation pressure, −40 to 150 °F−40 to 65 °C. Used in R-12 retrofits (MP39).

How to use ↓

Safety class A1Zeotropic blendGlide 9.45 °F at 40 °F evapGlide 5.25 K at 4.4 °C evap

PT lookup

Step 2 I know the
°F°C

Type a temperature to see the saturation pressure.

R-401A pressure temperature table

Liquid = bubble (subcooling). Vapor = dew (superheat). Below 0 psig: inches of mercury vacuum. Highlighted: 40 °F and 100 °F.Liquid = bubble (subcooling). Vapor = dew (superheat). Negative kPa = vacuum. Highlighted: 4 °C and 38 °C.

R-401A saturation pressure by temperature, °F and psig (vacuum in inches of mercury)
°FLiquid bubble, psigVapor dew, psig
-408.3 inHg13.8 inHg
-397.8 inHg13.4 inHg
-387.2 inHg12.9 inHg
-376.6 inHg12.4 inHg
-366.0 inHg11.9 inHg
-355.3 inHg11.4 inHg
-344.7 inHg10.9 inHg
-334.0 inHg10.3 inHg
-323.3 inHg9.8 inHg
-312.7 inHg9.2 inHg
-302.0 inHg8.6 inHg
-291.3 inHg8.1 inHg
-280.5 inHg7.5 inHg
-270.16.9 inHg
-260.56.2 inHg
-250.95.6 inHg
-241.25.0 inHg
-231.64.3 inHg
-222.03.6 inHg
-212.42.9 inHg
-202.92.2 inHg
-193.31.5 inHg
-183.70.8 inHg
-174.20.0
-164.60.4
-155.10.7
-145.51.1
-136.01.5
-126.51.9
-117.02.3
-107.52.8
-98.03.2
-88.53.6
-79.04.1
-69.64.5
-510.15.0
-410.75.5
-311.25.9
-211.86.4
-112.46.9
013.07.4
113.67.9
214.28.5
314.89.0
415.59.5
516.110.1
616.810.7
717.411.2
818.111.8
918.812.4
1019.513.0
1120.213.6
1220.914.3
1321.714.9
1422.415.5
1523.216.2
1623.916.9
1724.717.5
1825.518.2
1926.318.9
2027.119.6
2127.920.4
2228.821.1
2329.621.9
2430.522.6
2531.423.4
2632.324.2
2733.225.0
2834.125.8
2935.026.6
3036.027.4
3136.928.3
3237.929.1
3338.930.0
3439.930.9
3540.931.8
3641.932.7
3743.033.6
3844.034.6
3945.135.5
4046.236.5
4147.337.5
4248.438.5
4349.539.5
4450.740.5
4551.841.6
4653.042.6
4754.243.7
4855.444.8
4956.645.9
5057.947.0
5159.148.1
5260.449.3
5361.750.4
5463.051.6
5564.352.8
5665.754.0
5767.055.2
5868.456.5
5969.857.7
6071.259.0
6172.660.3
6274.161.6
6375.563.0
6477.064.3
6578.565.7
6680.067.1
6781.668.5
6883.169.9
6984.771.3
7086.372.8
7187.974.2
7289.575.7
7391.177.3
7492.878.8
7594.580.3
7696.281.9
7797.983.5
7899.785.1
79101.486.7
80103.288.4
81105.090.0
82106.891.7
83108.793.4
84110.595.2
85112.496.9
86114.398.7
87116.3100.5
88118.2102.3
89120.2104.1
90122.2106.0
91124.2107.8
92126.2109.7
93128.3111.7
94130.4113.6
95132.5115.6
96134.6117.6
97136.7119.6
98138.9121.6
99141.1123.7
100143.3125.7
101145.6127.8
102147.8130.0
103150.1132.1
104152.4134.3
105154.7136.5
106157.1138.7
107159.5141.0
108161.9143.2
109164.3145.5
110166.8147.8
111169.2150.2
112171.7152.6
113174.3154.9
114176.8157.4
115179.4159.8
116182.0162.3
117184.6164.8
118187.3167.3
119190.0169.9
120192.7172.4
121195.4175.1
122198.2177.7
123201.0180.3
124203.8183.0
125206.6185.7
126209.5188.5
127212.4191.3
128215.3194.1
129218.2196.9
130221.2199.7
131224.2202.6
132227.2205.5
133230.3208.5
134233.4211.5
135236.5214.5
136239.7217.5
137242.8220.6
138246.0223.7
139249.3226.8
140252.5229.9
141255.8233.1
142259.1236.3
143262.5239.6
144265.9242.9
145269.3246.2
146272.7249.5
147276.2252.9
148279.7256.3
149283.2259.7
150286.8263.2
R-401A saturation pressure by temperature, °C and kPa (negative = vacuum)
°CLiquid bubble, kPaVapor dew, kPa
-40-28.3-46.8
-39-24.7-43.9
-38-21.0-40.9
-37-17.1-37.8
-36-13.2-34.6
-35-9.0-31.2
-34-4.7-27.7
-33-0.3-24.1
-324.3-20.3
-319.1-16.3
-3014.0-12.3
-2919.1-8.0
-2824.4-3.6
-2729.90.9
-2635.55.6
-2541.410.5
-2447.415.6
-2353.620.8
-2260.126.2
-2166.731.8
-2073.537.6
-1980.643.6
-1887.949.8
-1795.456.2
-16103.162.8
-15111.069.7
-14119.276.7
-13127.784.0
-12136.391.5
-11145.399.2
-10154.4107.1
-9163.9115.3
-8173.6123.8
-7183.6132.5
-6193.8141.4
-5204.3150.7
-4215.2160.2
-3226.3169.9
-2237.6180.0
-1249.3190.3
0261.3200.9
1273.6211.8
2286.3223.0
3299.2234.5
4312.5246.3
5326.1258.4
6340.0270.9
7354.3283.6
8368.9296.7
9383.8310.2
10399.1323.9
11414.8338.1
12430.9352.6
13447.3367.4
14464.1382.6
15481.2398.2
16498.8414.1
17516.7430.5
18535.1447.2
19553.8464.3
20573.0481.8
21592.6499.7
22612.6518.1
23633.0536.8
24653.8556.0
25675.1575.6
26696.9595.7
27719.0616.2
28741.7637.1
29764.8658.5
30788.3680.4
31812.4702.7
32836.9725.5
33861.9748.8
34887.3772.6
35913.3796.8
36939.8821.6
37966.8846.9
38994.3872.7
391022.3899.0
401050.8925.9
411079.9953.3
421109.5981.2
431139.61009.7
441170.31038.7
451201.61068.3
461233.41098.5
471265.81129.3
481298.71160.6
491332.21192.6
501366.31225.1
511401.01258.3
521436.31292.0
531472.31326.4
541508.81361.4
551545.91397.1
561583.71433.4
571622.11470.4
581661.11508.0
591700.81546.3
601741.11585.3
611782.01625.0
621823.71665.3
631866.01706.4
641909.01748.2
651952.71790.7
Back to the lookup ↑

R-401A PT Chart

°F / psig · Safety class A1 · Zeotropic blend

refrigerantptchart.com

°FLiquidVapor
-408.3"13.8"
-397.8"13.4"
-387.2"12.9"
-376.6"12.4"
-366.0"11.9"
-355.3"11.4"
-344.7"10.9"
-334.0"10.3"
-323.3"9.8"
-312.7"9.2"
-302.0"8.6"
-291.3"8.1"
-280.5"7.5"
-270.16.9"
-260.56.2"
-250.95.6"
-241.25.0"
-231.64.3"
-222.03.6"
-212.42.9"
-202.92.2"
-193.31.5"
-183.70.8"
-174.20.0
-164.60.4
-155.10.7
-145.51.1
-136.01.5
-126.51.9
-117.02.3
-107.52.8
-98.03.2
-88.53.6
-79.04.1
-69.64.5
-510.15.0
-410.75.5
-311.25.9
-211.86.4
-112.46.9
013.07.4
113.67.9
214.28.5
314.89.0
415.59.5
516.110.1
616.810.7
717.411.2
°FLiquidVapor
818.111.8
918.812.4
1019.513.0
1120.213.6
1220.914.3
1321.714.9
1422.415.5
1523.216.2
1623.916.9
1724.717.5
1825.518.2
1926.318.9
2027.119.6
2127.920.4
2228.821.1
2329.621.9
2430.522.6
2531.423.4
2632.324.2
2733.225.0
2834.125.8
2935.026.6
3036.027.4
3136.928.3
3237.929.1
3338.930.0
3439.930.9
3540.931.8
3641.932.7
3743.033.6
3844.034.6
3945.135.5
4046.236.5
4147.337.5
4248.438.5
4349.539.5
4450.740.5
4551.841.6
4653.042.6
4754.243.7
4855.444.8
4956.645.9
5057.947.0
5159.148.1
5260.449.3
5361.750.4
5463.051.6
5564.352.8
°FLiquidVapor
5665.754.0
5767.055.2
5868.456.5
5969.857.7
6071.259.0
6172.660.3
6274.161.6
6375.563.0
6477.064.3
6578.565.7
6680.067.1
6781.668.5
6883.169.9
6984.771.3
7086.372.8
7187.974.2
7289.575.7
7391.177.3
7492.878.8
7594.580.3
7696.281.9
7797.983.5
7899.785.1
79101.486.7
80103.288.4
81105.090.0
82106.891.7
83108.793.4
84110.595.2
85112.496.9
86114.398.7
87116.3100.5
88118.2102.3
89120.2104.1
90122.2106.0
91124.2107.8
92126.2109.7
93128.3111.7
94130.4113.6
95132.5115.6
96134.6117.6
97136.7119.6
98138.9121.6
99141.1123.7
100143.3125.7
101145.6127.8
102147.8130.0
103150.1132.1
°FLiquidVapor
104152.4134.3
105154.7136.5
106157.1138.7
107159.5141.0
108161.9143.2
109164.3145.5
110166.8147.8
111169.2150.2
112171.7152.6
113174.3154.9
114176.8157.4
115179.4159.8
116182.0162.3
117184.6164.8
118187.3167.3
119190.0169.9
120192.7172.4
121195.4175.1
122198.2177.7
123201.0180.3
124203.8183.0
125206.6185.7
126209.5188.5
127212.4191.3
128215.3194.1
129218.2196.9
130221.2199.7
131224.2202.6
132227.2205.5
133230.3208.5
134233.4211.5
135236.5214.5
136239.7217.5
137242.8220.6
138246.0223.7
139249.3226.8
140252.5229.9
141255.8233.1
142259.1236.3
143262.5239.6
144265.9242.9
145269.3246.2
146272.7249.5
147276.2252.9
148279.7256.3
149283.2259.7
150286.8263.2

Liquid = bubble (use for subcooling). Vapor = dew (use for superheat). Italic " = inches of mercury vacuum. Bold rows: 40 °F and 100 °F. Reference only: always verify with the manufacturer’s data and your gauges.

R-401A PT Chart

°C / kPa (gauge) · Safety class A1 · Zeotropic blend

refrigerantptchart.com

°CLiquidVapor
-40-28.3-46.8
-39-24.7-43.9
-38-21.0-40.9
-37-17.1-37.8
-36-13.2-34.6
-35-9.0-31.2
-34-4.7-27.7
-33-0.3-24.1
-324.3-20.3
-319.1-16.3
-3014.0-12.3
-2919.1-8.0
-2824.4-3.6
-2729.90.9
-2635.55.6
-2541.410.5
-2447.415.6
-2353.620.8
-2260.126.2
-2166.731.8
-2073.537.6
-1980.643.6
-1887.949.8
-1795.456.2
-16103.162.8
-15111.069.7
-14119.276.7
-13127.784.0
-12136.391.5
-11145.399.2
-10154.4107.1
-9163.9115.3
-8173.6123.8
-7183.6132.5
-6193.8141.4
-5204.3150.7
°CLiquidVapor
-4215.2160.2
-3226.3169.9
-2237.6180.0
-1249.3190.3
0261.3200.9
1273.6211.8
2286.3223.0
3299.2234.5
4312.5246.3
5326.1258.4
6340.0270.9
7354.3283.6
8368.9296.7
9383.8310.2
10399.1323.9
11414.8338.1
12430.9352.6
13447.3367.4
14464.1382.6
15481.2398.2
16498.8414.1
17516.7430.5
18535.1447.2
19553.8464.3
20573.0481.8
21592.6499.7
22612.6518.1
23633.0536.8
24653.8556.0
25675.1575.6
26696.9595.7
27719.0616.2
28741.7637.1
29764.8658.5
30788.3680.4
31812.4702.7
°CLiquidVapor
32836.9725.5
33861.9748.8
34887.3772.6
35913.3796.8
36939.8821.6
37966.8846.9
38994.3872.7
391022.3899.0
401050.8925.9
411079.9953.3
421109.5981.2
431139.61009.7
441170.31038.7
451201.61068.3
461233.41098.5
471265.81129.3
481298.71160.6
491332.21192.6
501366.31225.1
511401.01258.3
521436.31292.0
531472.31326.4
541508.81361.4
551545.91397.1
561583.71433.4
571622.11470.4
581661.11508.0
591700.81546.3
601741.11585.3
611782.01625.0
621823.71665.3
631866.01706.4
641909.01748.2
651952.71790.7

Liquid = bubble (use for subcooling). Vapor = dew (use for superheat). Negative kPa = vacuum. Bold rows: 4 °C and 38 °C. Reference only: always verify with the manufacturer’s data and your gauges.

How to use

  1. Choose Temperature or Pressure and type the number. The answer shows straight away.
  2. Blends show two values: use vapor (dew) for superheat and liquid (bubble) for subcooling.
  3. Tap °C · kPa for metric. Below 0 psig, pressure is in inches of mercury (inHg) vacuum.
  4. Press Print pocket chart for a one-page chart (Letter or A4) for the van or the tool bag.

Back to top ↑

About this R-401A chart

This R-401A pressure temperature chart gives the saturation pressure for every degree, in psig with °F or kPa (gauge) with °C. As a blend, it has a liquid (bubble) and a vapor (dew) column. Below 0 psig the °F table shows inches of mercury (inHg) vacuum.

Source: manufacturer and supplier charts (Honeywell, Arkema, National Refrigerants). Reference only: always verify with the manufacturer’s data and your gauges.

FAQ

What is the R-401A pressure at 40 °F?

36.5 psig vapor (dew) and 46.2 psig liquid (bubble) at saturation, from the table above.

What is the R-401A pressure at 100 °F?

125.7 psig vapor (dew) and 143.3 psig liquid (bubble) at saturation.

Which column do I use for superheat and subcooling?

Use vapor (dew) for superheat and liquid (bubble) for subcooling. R-401A has 9.45 °F of glide at a 40 °F evaporator, so the two columns differ.

Coming from Check & Charge or PT Pro? See the free offline alternative (no login).

Related